Designed for Training, Academic Research, and Assay Learning on Real-Time PCR systems
q-PCR 2-Channel Real-Time PCR Kit is a
ready-to-use master mix formulated for high-sensitivity
detection using dual-labelled hydrolysis probes. Designed for multiplex
detection, this RUO-grade
mix enables simultaneous quantification of an exogenous control
(Bacteriophage DNA) and
an endogenous control (β-actin) in a single reaction.
The kit uses a probe-based q-PCR master mix pre-configured for:
●FAM channel – To detect DNA template
●HEX channel – To detect β-actin (internal control)
| Product Code | Description | Pack Size |
|---|---|---|
| GLR001 | q-PCR 2-Channel Real Time PCR Kit | 10 Rxn |
| GLR001-C | Custom Academic Pack | On Request |
Designed for Training, Academic Research, and Assay Learning on Real-Time PCR systems
RT q-PCR 2-Channel PCR Kit is a Research Use Only
(RUO) tool, ideal for educational
institutions, molecular biology teaching labs, and entry-level research
programs. It
enables reverse transcription and real-time detection in a single-tube
workflow.
The kit uses a probe-based RT-PCR master mix pre-configured for:
●FAM channel – To detect DNA template
●HEX channel – To detect β-actin (internal control)
| Product Code | Description | Pack Size |
|---|---|---|
| GLR002 | RT q-PCR 2 Channel RT-PCR Kit | 10 Rxn |
| GLR002-C | Custom Academic Pack | On Request |
Reliable, Affordable, and Ideal for Gene Expression Studies, Assay Validation, and Educational Training.
SYBR Green-based Real-Time PCR kit is a
ready-to-use, RUO-grade master mix optimized for
high-efficiency DNA amplification analysis and educational training
purposes. It includes
validated primers for β-actin, which serves as a consistent internal control
for normalization
in q-PCR experiments.
Ideal for routine lab assays, academic training, and gene expression
workflows using
intercalating dye chemistry.
| Product Code | Description | Pack Size |
|---|---|---|
| GLR003 | SYBR Green q-PCR Kit | 10 Rxn |
| GLR003-C | Custom Academic Pack | On Request |
Empowering students to master the fundamentals of PCR through guided, real-world experimentation.
Conventional PCR Teaching Kits are designed
specifically for colleges, universities, training
centers, and workshop facilitators looking to provide students with
hands-on experience
in end-point PCR. These kits contain all the reagents and consumables
needed to teach the
core principles of PCR and DNA amplification.
Each kit includes target-specific primers, positive control DNA, and a
PCR-ready master mix —
making it an ideal plug-and-play solution for instructors and students.
●Ready-to-use reagents: no need for extra preparation
●Includes target-specific primers (e.g., for β-actin)
●Positive control DNA provided for successful amplification
●Optimized for 25–35 cycles on standard thermal cyclers
●Suitable for agarose gel electrophoresis analysis
| Product Code | Description | Pack Size |
|---|---|---|
| GLR004-25X | Conventional PCR Teaching Kit | 25 reactions |
| GLR004-50X | Conventional PCR Teaching Kit | 50 reactions |
| GLR004-C | Custom Academic Pack | On Request |
The QTaq Influenza A Real-Time RT-PCR Test Kit is designed for the qualitative and quantitative detection of Influenza A viral nucleic acid from a range of respiratory specimens. These include upper respiratory samples such as nasopharyngeal swabs, nasal swabs, and combined nasopharyngeal/throat swabs, as well as lower respiratory tract specimens like bronchoalveolar lavage, bronchial wash, tracheal aspirate, sputum, and lung tissue. Influenza A viruses are negative-sense, single-stranded, segmented RNA viruses known for their high mutation rates, particularly in surface proteins. This variability contributes to their potential to cause seasonal outbreaks and global pandemics. The QTaq test kit targets the conserved M1 and M2 gene regions of Influenza A, ensuring accurate detection. The included PCR reaction mix enables real t ime monitoring of viral RNA amplification through fluorescence signals. To enhance test reliability, the system also incorporates an endogenous internal control.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | M1 & M2 gene of Influenza A |
| Specimen | upper and lower respiratory specimens |
| Specificity | Influenza A subtypes H1N1,H3N2 |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq Influenza B Real-Time RT-PCR Test Kit enables the qualitative and quantitative detection of Influenza B viral nucleic acid from both upper and lower respiratory specimens. These include nasopharyngeal swabs, nasal swabs, combined nasopharyngeal/throat swabs, and lower respiratory samples such as bronchoalveolar lavage, bronchial wash, tracheal aspirate, sputum, and lung tissue. Influenza B viruses, part of the Orthomyxoviridae FAMily, circulate primarily in humans and are responsible for seasonal respiratory infections. Unlike Influenza A, Influenza B viruses evolve more slowly but still contribute significantly to annual f lu epidemics. The QTaq test kit targets conserved regions of the M1 and BM2 genes of Influenza B, ensuring accurate detection. Using the provided PCR reaction mix, viral amplification is tracked in real time through fluorescence signals. An endogenous internal control is included to validate each test and enhance result reliability.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | M1 & M2 gene of Influenza B |
| Specimen | upper and lower respiratory specimens |
| Specificity | Influenza B subtypes B/Victoria lineage, B/Yamagata lineage |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq RSV A&B Real-Time RT-PCR Test Kit is designed for the qualitative and quantitative detection of nucleic acids from Respiratory Syncytial Virus (RSV) subtypes A and B in both upper and lower respiratory specimens. Valid sample types include nasopharyngeal swabs, nasal swabs, dual nasopharyngeal/throat swabs, and lower respiratory tract samples such as bronchoalveolar lavage, bronchial wash, tracheal aspirate, sputum, and lung tissue. Respiratory Syncytial Virus (RSV), also known as human respiratory syncytial virus (hRSV) or human orthopneumovirus, is a highly contagious virus that causes respiratory tract infections. It is a negative-sense, single-stranded RNA virus and is classified into two subgroups—RSV A and RSV B—based on genetic and antigenic differences in its structural proteins. The QTaq RSV A&B kit targets conserved sequences of the RSV polymerase gene, ensuring reliable detection of both subtypes. Using the included PCR reaction mix, amplification can be monitored in real-time through increasing fluorescence signals, measured by a compatible PCR instrument. An endogenous internal control is included to verify sample integrity and enhance result accuracy.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | polymerise gene of Respiratory syncytial virus |
| Specimen | upper and lower respiratory specimens |
| Specificity | RSV A and B |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
Middle East Respiratory Syndrome (MERS) Real Time RT-PCR Kit is designed for the qualitative/quantitative detection of nucleic acids from Nasopharyngeal swabs, Oropharyngeal specimens, Serum and Seminal Plasma of infected patients. The results can be used to assist diagnosis of patients with MERS infection and provide molecular diagnostics. The test results of this product are for clinical reference only and should not be used as the only standard for clinical diagnosis. It is recommended to conduct a comprehensive analysis by combining the test results with clinical symptoms and other laboratory tests.
The Human Metapneumovirus (HMPV) Real-Time RT-PCR Test is a highly sensitive diagnostic assay designed to detect the RNA of HMPV, a respiratory virus known to cause illnesses ranging from mild cold-like symptoms to severe respiratory conditions such as pneumonia. This test is particularly crucial for identifying infections in vulnerable populations, including young children, the elderly, and individuals with weakened immune systems. Utilizing real-time reverse transcription polymerase chain reaction (RT PCR) technology, the assay ensures accurate and specific detection of viral RNA, even at low concentrations. The rapid turnaround time enables timely diagnosis and intervention, which is essential for effective clinical management. The test is validated for use with a variety of respiratory specimens, including nasopharyngeal swabs and aspirates. Its high reliability makes it an invaluable tool for infection control and surveillance in healthcare settings.
The Chlamydophila psittaci Real-Time PCR Test is a molecular diagnostic assay developed to detect the DNA of Chlamydophila psittaci, the bacterial agent responsible for psittacosis—also known as parrot fever—in humans. This zoonotic pathogen is primarily transmitted through contact with infected birds, especially pet birds such as parrots, parakeets, and cockatiels. Utilizing real-time PCR technology, the test offers rapid, accurate, and highly sensitive detection of the bacterium in a range of clinical specimens, including blood, respiratory secretions, and tissue samples. Early detection through this assay supports prompt treatment and helps prevent complications and further transmission. The test is especially valuable in cases of atypical pneumonia or flu-like symptoms linked to bird exposure. Its precision and speed make it a reliable tool for both clinical diagnostics and epidemiological investigations.
It is a waterborne pathogen primarily transmitted through the inhalation of aerosolized water droplets from sources such as showers, cooling towers, and fountains. Once inhaled, it can cause a severe form of pneumonia known as Legionnaires' disease. Common symptoms include high fever, chills, cough, and difficulty breathing. Prompt diagnosis and treatment are essential, as the infection can be serious, particularly in older adults or those with weakened immune systems.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Kit Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
Reliable, high-yield nucleic acid purification kits for research and training applications
Our Nucleic Acid Extraction Kits offer two versatile platforms — Magnetic Bead Based and Spin Column-Based — designed for efficient isolation of DNA or RNA from a variety of sample types, including swabs, blood, tissue, saliva, and cultured cells. Suitable for molecular diagnostics research, PCR/q-PCR workflows, and academic labs, these kits ensure high-purity nucleic acid recovery with consistent results.
| Feature | Magnetic Bead-Based Kit | Column-Based Kit |
|---|---|---|
| Principle | Magnetic bead binding & separation | Silica membrane spin-column |
| Workflow Type | Manual or Automatable | Manual only |
| Sample Types | Swab, blood, saliva, tissue, cells | Swab, blood, saliva, tissue, cells |
| Equipment Required | Magnetic stand or instrument | Microcentrifuge |
| Time to Extract | ~15–20 minutes | ~20–30 minutes |
| Binding Capacity | High – suitable for low/high input | Moderate – optimal for standard input |
| Purity (A260/280) | 1.8–2.0 | 1.8–2.0 |
| Yield Range | 20–50 ng/μL (depending on sample) | 15–40 ng/μL |
| Reusability of Equipment | Magnetic stand reusable | Spin columns single-use |
| Automation Compatibility | ✓ Yes | ✘ No |
| Storage Conditions | 2–8°C or RT | 2–8°C or RT |
| Downstream Compatibility | PCR, RT-PCR, q-PCR | PCR, RT-PCR, q-PCR |
| Pack Size | 10 Rxn | |
| Product Code | Product Name |
|---|---|
| Magnetic Bead Based Extraction Kit | |
| GLXM001 | QTaq XT Magnetic Particle Technology Specimen: Urine, Saliva, Cell Culture fluid, Swabs, CSF, Cell Scrapings, WB, Serum, Plasma and Tissue |
| GLXM002 | QTaq XT Magnetic Particle Technology Specimen: Faecal Samples |
| GLXM003 | QTaq XT Magnetic Particle Technology Specimen: Sputum |
| GLXM004 | QTaq XT Magnetic Particle Technology Specimen: Paraffin Embedded Formalin Based Tissue (PEFBT) |
| GLXM005 | QTaq XT Magnetic Particle Technology Specimen: Bacterial spore extraction |
| GLXM006 | QTaq XT Magnetic Particle Technology Specimen: Feather tip |
| Product Code | Product Name |
|---|---|
| Column Based Extraction Kit | |
| GLXC001 | QTaq XT Spin Column Technology Specimen: WB, Serum, Plasma, Urine, Saliva, Cell Culture fluid, Swabs, CSF, Cell Scrapings |
| GLXC002 | QTaq XT Spin Column Technology Specimen: WB, Serum, Plasma, Urine, Saliva, Cell Culture fluid, Swabs, Tissue & Faecal |
| GLXC003 | QTaq XT Spin Column Technology Specimen: Sputum |
| GLXC004 | QTaq XT Spin Column Technology Specimen: Paraffin Embedded Formalin Based Tissue (PEFBT) |
| GLXC005 | QTaq XT Spin Column Technology Specimen: Feather tip |
The QTaq Rotavirus Real-Time RT-PCR Test Kit, developed by Genes for Life, is designed for the qualitative detection of Rotavirus nucleic acids in stool samples from patients with suspected infection. Rotavirus, a genus of double-stranded RNA viruses from the Reoviridae FAMily, is highly contagious and a leading cause of acute gastroenteritis, particularly in infants and young children. It can result in severe diarrhea, vomiting, fever, abdominal pain, and dehydration. While commonly affecting children, it can also impact adults, especially in close-contact environments. The QTaq test targets a conserved region of the NSP3 gene specific to Rotavirus, ensuring high specificity and sensitivity. Using the included PCR reaction mix, real-time amplification is monitored through fluorescent signal detection on a compatible PCR instrument. An endogenous internal control is integrated into the system to ensure test validity and result accuracy.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | NSP3 gene of Rotavirus |
| Specimen | Stool sample |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq Campylobacter Real-Time PCR Test Kit is intended for the qualitative detection of Campylobacter nucleic acids in stool samples from patients with suspected infections. Campylobacter is a genus of Gram-negative gastroenteric bacteria, with Campylobacter jejuni being the most common species associated with gastroenteritis or stomach flu. Infections typically present with symptoms such as diarrhea, vomiting, stomach cramps, and fever. Developed by Genes for Life, the QTaq Campylobacter Test Kit targets a conserved region of the 16S rRNA gene, enabling accurate identification of the pathogen. Using the included PCR reaction mix, amplification of the target DNA is monitored in real-time via fluorescence signals on compatible PCR instruments. The system also includes an endogenous internal control to ensure test validity and reliability.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | 16S rRNA gene of Campylobacter |
| Specimen | Stool sample |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq Entamoeba Real-Time PCR Test Kit is designed for the qualitative detection of Entamoeba histolytica nucleic acids in stool samples from individuals with suspected amebiasis. Entamoeba histolytica is an anaerobic, parasitic amoebozoan that infects the human gastrointestinal tract, with the potential to invade the intestinal lining and spread to other organs—most commonly the liver. Amebiasis, caused by this protozoan parasite, can range from mild gastrointestinal discomfort to more severe invasive disease. Developed by Genes for Life, the QTaq test kit targets a conserved region of the 18S rRNA gene, ensuring high specificity and sensitivity. The included PCR reaction mix enables real-time monitoring of DNA amplification through fluorescent signal detection using a compatible PCR instrument. An endogenous internal control is also incorporated to validate the accuracy and reliability of each test result.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | 18S rRNA gene of Entamoeba histolytica |
| Specimen | Stool sample |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq Cryptosporidium Real-Time PCR Test Kit is developed for the qualitative detection of Cryptosporidium nucleic acids in stool samples from patients with suspected infection. Cryptosporidium is a genus of apicomplexan parasitic alveolates known to cause cryptosporidiosis, a disease that can affect both the gastrointestinal and respiratory systems. Symptoms commonly include watery diarrhea, and in some cases, a persistent cough— especially in immunocompromised individuals, though immunocompetent patients may also be affected. Produced by Genes for Life, the QTaq test kit targets a conserved region of the DNAJ-like protein gene, ensuring specific and accurate detection. The included PCR reaction mix allows for real-time amplification monitoring through fluorescence signals on a compatible PCR instrument. To ensure test reliability, the system also incorporates an endogenous internal control.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | DNAJ-like protein gene of Cryptosporodium |
| Specimen | Stool sample |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq Shigella Real-Time PCR Test Kit, developed by Genes for Life, is designed for the qualitative detection of Shigella nucleic acids in stool samples from patients with suspected shigellosis. Shigella is a genus of Gram-negative, facultative anaerobic, non-spore-forming, nonmotile, rod-shaped bacteria. It is responsible for shigellosis, an intestinal infection characterized by diarrhea (often bloody), fever, and abdominal cramps. Transmission typically occurs through contaminated food, water, or direct contact with an infected person, making it a common concern in both clinical and public health settings. The QTaq assay specifically targets the conserved ipaH gene, ensuring high specificity in detecting Shigella species. With the included PCR reaction mix, real-time amplification is monitored by detecting an increasing f luorescence signal using a compatible PCR instrument. The system also features an endogenous internal control to confirm the integrity and accuracy of each test run.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | ipaH gene of Shigella |
| Specimen | Stool sample |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq Salmonella Real-Time PCR Test Kit, developed by Genes for Life, is intended for the qualitative detection of Salmonella nucleic acids in stool samples from individuals with suspected salmonellosis. Salmonella is a genus of Gram-negative, rod-shaped bacteria belonging to the Enterobacteriaceae FAMily. It is a common cause of bacterial gastroenteritis, known as salmonellosis, which primarily affects the intestinal tract. Infection typically occurs through the consumption of contaminated food or water, as the bacteria are commonly present in the intestines of humans and animals and are shed through feces. The QTaq test targets a conserved region of the ttrC gene, specific to Salmonella species, for reliable detection. The included PCR reaction mix allows for quantitative real-time monitoring of DNA amplification using fluorescence detection on compatible PCR instruments. An endogenous internal control is integrated to ensure the accuracy and validity of test results.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | ttrC gene of Salmonella |
| Specimen | Stool sample |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq E. coli Real-Time PCR Test Kit is designed for the qualitative detection of Escherichia coli (E. coli) nucleic acids in stool samples from patients with suspected infection. E. coli is a Gram-negative, rod-shaped bacterium commonly found in the lower intestines of warm blooded organisms. While most strains are harmless or cause mild, short-lived diarrhea, certain types—such as E. coli O157:H7—can lead to severe abdominal cramps, bloody diarrhea, and vomiting. E. coli O157:H7 produces Shiga toxin, one of the most potent bacterial toxins, which is responsible for causing serious intestinal infections. Developed by Genes for Life, the QTaq test kit targets a conserved sequence of the lacY gene, enabling specific and accurate pathogen detection. Using the included PCR reaction mix, amplification of the target DNA is tracked in real-time via fluorescent signal detection on a compatible PCR instrument. An endogenous internal control is integrated into the system to ensure the validity and reliability of test results.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | lacY gene of E. coli |
| Specimen | Stool sample |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq Giardia Real-Time PCR Test Kit is designed for the qualitative detection of Giardia nucleic acids in stool samples from patients with suspected giardiasis. Giardia is a genus of anaerobic, flagellated protozoan parasites belonging to the phylum Metamonada. The primary causative agent of giardiasis is Giardia duodenalis (also known as G. lamblia or G. intestinalis), which infects the small intestines of humans and animals. Giardiasis is an intestinal infection characterized by symptoms such as stomach cramps, bloating, nausea, and episodes of watery diarrhea. The parasite is commonly transmitted through contaminated water, food, soil, or surfaces exposed to feces from infected individuals or animals. Developed by Genes for Life, the QTaq test kit targets a conserved region of the 18S rRNA gene to ensure precise and specific detection. The included PCR reaction mix enables real-time amplification monitoring via fluorescence signal using a compatible PCR instrument. The system also incorporates an endogenous internal control to ensure test reliability and performance accuracy.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | 18S rRNA gene of Giardia |
| Specimen | Stool sample |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq Clostridium difficile Real-Time PCR Test Kit is designed for the qualitative detection of Clostridium difficile nucleic acids in stool samples from patients with suspected infection. Clostridium difficile (commonly referred to as C. difficile) is a Gram-positive, spore-forming bacterium known for producing toxins that cause a serious form of antibiotic-associated diarrhea. C. difficile infection (CDI) can range in severity from mild diarrhea to life-threatening inflammation of the colon. It typically occurs following antibiotic treatment, which disrupts the normal gut flora and allows C. difficile to grow unchecked and release harmful toxins. Developed by Genes for Life, the QTaq test kit targets the conserved sequences of the tcdA and tcdB toxin genes, ensuring accurate and specific detection. The included PCR reaction mix enables real-time monitoring of DNA amplification via fluorescence signals, using a compatible real-time PCR instrument. The system also features an endogenous internal control to verify the integrity and performance of each test run.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | tcdA & tcdB gene of Clostridium difficile |
| Specimen | Stool sample |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq Yersinia Real-Time PCR Test Kit, developed by Genes for Life, is intended for the qualitative detection of Yersinia enterocolitica nucleic acids in stool samples from patients suspected of yersiniosis. Yersinia enterocolitica is a Gram-negative, coccobacillus-shaped, facultative anaerobic bacterium belonging to the Yersiniaceae FAMily. It is typically transmitted through the consumption of raw or undercooked pork and other contaminated food products. The resulting infection, known as yersiniosis, can lead to acute diarrhea, mesenteric adenitis, terminal ileitis, and symptoms that may mimic appendicitis (pseudoappendicitis). The QTaq test targets the conserved foxA gene specific to Y. enterocolitica, ensuring high specificity and sensitivity. The provided PCR reaction mix enables real-time amplification monitoring via increasing fluorescence signals, using a compatible PCR instrument. An endogenous internal control is included to validate each reaction and ensure result reliability.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | 16S rRNA gene of Campylobacter |
| Specimen | Stool sample |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq Vibrio Real-Time PCR Test Kit, developed by Genes for Life, is designed for the qualitative detection of Vibrio cholerae nucleic acids in stool samples from patients with suspected cholera infection. Vibrio cholerae is a Gram-negative, facultative anaerobic, comma-shaped bacterium responsible for causing cholera—a severe diarrheal illness that can become life-threatening if untreated. The disease is most often linked to contaminated water or food and is primarily caused by the toxigenic strains of V. cholerae serogroups O1 and O139.
The QTaq test targets the conserved ompW gene, enabling highly specific detection of V. cholerae. The provided PCR reaction mix facilitates real-time amplification, which is quantitatively monitored through fluorescence detection on a compatible PCR instrument. An endogenous internal control is included in the assay to ensure accuracy and test validity.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | ompW gene of Vibrio cholerae |
| Specimen | Stool sample |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq Hepatitis A Virus Real-Time RT-PCR Test Kit, developed by Genes for Life, is intended for the qualitative detection of Hepatitis A Virus (HAV) nucleic acid in stool samples of suspected individuals. Hepatitis A Virus is a non-enveloped RNA virus that primarily spreads via the fecal-oral route, often through contaminated food or water. HAV causes acute liver infection and is a significant public health concern, especially in areas with poor sanitation. Infection typically leads to symptoms such as fatigue, nausea, abdominal discomfort, and jaundice. The real-time PCR assay allows quantitative monitoring through fluorescence, with each reaction supported by an endogenous internal control to ensure result integrity and reliability.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Kit Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Sensitivity | 95% |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The Helicobacter pylori real-time PCR test kit for a gastrointestinal (GI) panel is a molecular diagnostic tool designed to detect the presence of H. pylori bacteria in clinical samples, commonly gastric biopsies or stool specimens. Utilizing the polymerase chain reaction (PCR) technique, the kit amplifies specific DNA sequences unique to H. pylori, enabling highly sensitive and specific identification of the pathogen. This allows for accurate diagnosis and timely treatment of H. pylori-related infections. Real-time PCR also offers the advantage of rapid turnaround times and quantitative results. It reduces the risk of false negatives by detecting even low levels of bacterial DNA. These kits are widely used in clinical laboratories as part of comprehensive GI pathogen panels.
Convenient, contamination-free, and stable master mix for real-world lab and field use.
The Lyophilized PCR Master Mix is a single-use,
room-temperature stable PCR reagent
system packaged in individually sealed strip (8 tubes). It is available
in formulations
for Conventional PCR, Real-Time q-PCR, and Reverse Transcription PCR
(RT-PCR). Designed
for both lab-based and point-of-use applications, this format ensures
maximum stability,
accuracy, and convenience.
Each 2-strip pack includes, 2 nos of 8-tube strips, with each strip
individually packed to
reduce handling and contamination risk — ideal for field research,
training kits, and routine
PCR labs.
●Lyophilized single-use format – No cold chain needed
● Each strip individually sealed – Long-term stability and contamination control
●Just add sample and primers
●Stable at room temperature for 12 months
| PRODUCT VARIANTS & ORDERING INFORMATION | ||||
|---|---|---|---|---|
| Product Code | Catalog No. | Type | Application | Pack Size |
| LYO-PCR | GLR005 | Standard PCR | Endpoint amplification | 2 STRIPS, 10 STRIP, BULK |
| LYO-RT | GLR006 | One-Step RT-PCR | RNA to cDNA & amplification | 2 STRIPS, 10 STRIP, BULK |
| 2 Strip - 16 Wells; 10 Pack (160 Tubes) - 16 Tubes X 10 Packs; Bulk - Custom Packing As Per Requirement | ||||
The QTaq HCV Real-Time RT-PCR Test Kit enables accurate qualitative and quantitative detection of Hepatitis C virus RNA from whole blood, plasma, or serum samples. Hepatitis C is a viral infection that causes progressive liver damage, including scarring (fibrosis) and reduced liver function. Early and sensitive detection is crucial for effective treatment and disease monitoring. This kit specifically targets a conserved region of the HCV poly gene, ensuring reliable detection across diverse HCV strains. Using the provided RT-PCR reaction mix, amplification of viral RNA is tracked in real-time through fluorescence signals detected by a compatible real-time PCR system. An endogenous internal control is also integrated into the assay to confirm sample quality and the accuracy of results.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | P gene of HCV |
| Specimen | Whole Blood, Plasma, Serum |
| Specificity | HCV genotype A-H |
| Sensitivity | 95% |
| Traceability | 4th WHO International Standard for HCV DNA |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
The QTaq HIV 1&2 Real-Time RT-PCR Test Kit is designed for the qualitative and quantitative detection of Human Immunodeficiency Virus (HIV-1 and HIV-2) RNA in whole blood, plasma, or serum samples. HIV is a retrovirus that causes HIV infection and acquired immunodeficiency syndrome (AIDS)—a progressive condition that severely weakens the immune system. Early detection plays a vital role in disease management and treatment outcomes. This kit targets highly conserved sequences in the pol and gag genes of both HIV-1 and HIV-2, ensuring broad detection across subtypes and high analytical accuracy. Using the provided RT-PCR reaction mix, real-time amplification is monitored through fluorescence signals, detected by a compatible real t ime PCR system. An integrated endogenous internal control is included to validate sample integrity and ensure reliable test performance.
| Technology | Real-time PCR, Ready to use test |
|---|---|
| Configuration | 10 Test/ Kit with 2 positive and negative controls |
| Target Sequence | pol and gag gene of HIV-1&2 |
| Specimen | Whole Blood, Plasma, Serum |
| Specificity | HIV subtypes A, B, C, D, A/E, F, G, AG-GH, N, O, J, CRF |
| Sensitivity | 95% |
| Traceability | 4th WHO International Standard for HIV-1 RNA 2nd WHO International Standard for HIV-2 RNA |
| Instrument Compatibility | Compatible with Applied Biosystems (ABI) 7500, BioRad CFX96, QIAGEN Rotor Gene Q and other PCR instruments with FAM, HEX/VIC channels |
| Storage | Room Temperature |
A fast, robust, and equipment-minimal solution for isothermal nucleic acid amplification — ideal for labs, diagnostics, and field deployment.
LAMP Master Mix is a single-use lyophilized
reagent format, pre-dispensed into 0.2 mL PCR
tubes, enabling simple and rapid isothermal amplification of nucleic
acids without the need
for a thermal cycler. These reagents are optimized for Loop-mediated
Isothermal
Amplification (LAMP) — known for its speed, sensitivity, and minimal
instrumentation
requirements.
Each tube is vacuum-sealed and stable at ambient temperature, making it
highly suitable
for point-of-care diagnostics, mobile testing labs, resource-limited
settings, and training
kits.
●Lyophilized, single-use tubes – pre-aliquoted, individually packed
●Supports DNA and RNA templates
● Ready-to-use: just add primers and sample
● No thermal cycler required
● Visual detection via colorimetric, fluorescent, or turbidimetric readouts (variant specific)
| Product Code | Description | Pack Size |
|---|---|---|
| GLR007 | LAMP Master Mix | 16 Rxn |
| GLR007-C | Custom Pack | On Request |
Optimized for fast, efficient, and scalable DNA/RNA binding in molecular workflows
Magnetic Beads are superparamagnetic particles
engineered for high-yield nucleic acid
isolation. Designed for use in both manual and automated systems, they
offer excellent
performance across a variety of sample types including clinical swabs,
saliva, blood, cell
lysates, and environmental samples.
Ideal for PCR, q-PCR, RT-PCR, and LAMP workflows, these beads are
compatible
with cartridge systems, lab automation, and manual magnetic stands —
making them
suitable for both diagnostics and research applications.
● Superparamagnetic beads with uniform size distribution
● High binding efficiency for DNA/RNA
●Compatible with a wide range of lysis buffers
● No centrifugation needed – ideal for automation
● Reproducible performance in high-throughput formats
● Stable at room temperature with long shelf life
| Product Code | Description | Pack Size |
|---|---|---|
| GLR008 | Magnetic Bead – 5mL | 100 Rxn |
| GLR008-C | Custom Pack | On Request |
Engineered for consistent thermal performance and compatibility with all standard PCR instruments.
The QTaq range of PCR strips and caps are precision-molded consumables designed to deliver uniform heat transfer, minimal evaporation, and perfect sealing for PCR and q-PCR reactions. Available in both Low Profile and High-Profile configurations, these strips are compatible with most standard thermal cyclers and real-time PCR instruments.
| Product Code | Variant | Description | Compatibility |
|---|---|---|---|
| GLC001 | Low Profile Strips | 0.1 mL well volume | Ideal for fast cycling and q-PCR |
| GLC002 | High Profile Strips | 0.2 mL well volume | Suitable for conventional PCR & standard blocks |
| GLC003 | Flat Caps | Individually attached strip caps | Excellent sealing for q-PCR |
| GLC004 | Domed Caps | Higher clearance caps | Best for conventional PCR |
| Product Code | Description | Pack Size |
|---|---|---|
| GLC001 | 8-Tube Strip, Low Profile | 125 Strips |
| GLC002 | 8-Tube Strip, High Profile | 125 Strips |
| GLC003 | Flat Cap Strips (8 caps/strip) | 125 Strips |
| GLC004 | Domed Cap Strips (8 caps/strip) | 125 Strips |
| GLC004-C | Custom Pack | On Request |
Accurate, convenient, and contamination-free solution for microscopy-based cell quantification
Cell Counting Slides are ready-to-use, disposable chambers designed for fast and accurate enumeration of cells under a microscope or automated cell counter. These slides eliminate the need for traditional hemocytometers, cover slips, and tedious cleaning processes — enabling faster workflows and high reproducibility. Each slide is designed with dual counting chambers and precision depth spacing, allowing reliable cell quantification in biological research, cell culture, and diagnostics.
●Designed for manual and automated cell counters
● No washing or re-use – ensures sterility and accuracy
● Compatible with trypan blue and other viability dyes
● Made from optical-grade plastic for excellent clarity
● Reduces sample volume and time per count
| Product Code | Description | Pack Size |
|---|---|---|
| GLC005-S50 | Cell Counting Slides – Dual Chamber | 50 slides/box |
| GLC005-S100 | Cell Counting Slides – Dual Chamber | 100 slides/box |
| GLC006-S25 | Sterile Cell Counting Slides (on request) | 25 pack |
| GLC006-S50 | Sterile Cell Counting Slides (on request) | 50 pack |
Real-time PCR machines provide fast, accurate, and sensitive detection of genetic material, making them essential tools for diagnostics, research, and molecular biology.
Real-Time PCR machine is a portable fluorescence
quantitative PCR instrument with 4
channels and 16 & 32 well block, the system incorporates innovative
optical technologies
with powerful software to provide maximal reliability and efficiency for
your entire real time
PCR assay.
Application: The product can be used for real-time detection in
veterinary, human, aquatic
and food diagnostics, forest farm, breeding farm and water source. It is
used for rapid
diagnosis of disaster and epidemic disease, inspection and quarantine in
the field of food
safety and scientific research in biological laboratories.
| Product Code | Variant | Description | Compatibility |
|---|---|---|---|
| GLC001 | Low Profile Strips | 0.1 mL well volume | Ideal for fast cycling and q-PCR |
| GLC002 | High Profile Strips | 0.2 mL well volume | Suitable for conventional PCR & standard blocks |
| GLC003 | Flat Caps | Individually attached strip caps | Excellent sealing for q-PCR |
| GLC004 | Domed Caps | Higher clearance caps | Best for conventional PCR |
| Product Code | Description | Pack Size |
|---|---|---|
| GL-CQ41 | 4 channel and 16-well block | Supports a sample capacity of 16 × 0.2 ml and is compatible with clear 0.2 ml PCR tubes or 8-tube strips. |
| GL-CQ42 | 4 channels and 32-well block | Features a sample capacity of 32 × 0.2 ml with a 16-well double block design and is compatible with clear 0.2 ml PCR tubes or 8-tube strips. |
Nucleic Acid Extraction System is an automated solution designed to efficiently isolate high quality DNA/RNA for accurate PCR assays.
Designed with an optimized built-in protocol for
efficient mixing and tapping, this nucleic
acid extraction system ensures uniform magnetic bead suspension,
delivering higher DNA
yields with consistent results. Its advanced automation shortens
processing time, reduces
human error, and improves reproducibility—making it an indispensable
solution for both
clinical and research laboratories.
Applications: This system is ideal for extracting highly purified
nucleic acids from a variety of
sample types, including those used in veterinary, human, aquatic, and
food diagnostics, as
well as genetic identity testing, forensic science, biomedical research,
and gene expression
analysis.
| Product Code | Description | Pack Size |
|---|---|---|
| XT4 | 4 Sample Configurations | The system utilizes magnetic bead-based extraction technology and can process up to 4 samples simultaneously. |
| XT32 | 32 Sample Configurations | The system employs magnetic bead-based extraction technology and is capable of processing up to 32 samples at a time. |
●10.1-inch large touch screen operation
● High precision and accurate results.
● Software: Single wavelength and double wavelengths detection methods.
| Model | GLE01 |
|---|---|
| Measurement Channel | Vertical 8 optical channels |
| Plate Type | 96-well microplate |
| Wavelength Range | 340~850nm |
| Filter | Standard 5 wavelengths of 340, 405, 450, 492, 630nm Optional: Up to 10 wavelengths. |
| Reading Range | 0.000 ~ 4.500Abs |
| Linear Range | 0.000 ~ 3.500Abs |
| Resolution | 0.0001Abs |
| Repeatability | CV ≤ 1.0% |
| Stability | ≤ ±0.003Abs |
| Sensitivity | ≥ 0.01 mg/L |
| Channel Difference | ≤ 0.02Abs |
| Vibration Plate Function | 5 kinds of vibration plate function, adjustable 0~255s |
| Incubation Function | Time Range: 0~60min Temp. Range: RT +4℃ ~ 50℃ |
| Power Supply | AC100-240V, 50/60Hz |
| Instrument Size (W*D*H) | 495 × 340 × 370 mm |
| Package Size (W*D*H) | 610 × 440 × 475 mm |
| Net/Gross Weight | 12 / 14 kg |
●Microcomputer control, automatically complete the plate washing operation.
● The liquid level sensing function automatically detects the liquid level and automatically alarms when the cleaning liquid is insufficient, and the waste liquid is overflowing.
●The user-friendly operating system allows users to customize the plate type, set the number of washes, the amount of wash solution, the way to wash the plate, the suction point, the soaking and shaking time and other parameters.
● The wash head is self-balancing, has two-point aspiration, and performs bottom flushing.
●2 kinds of Automatic washing, Soaking and Shaking, to reduce the interference adsorption during the reaction; time adjustable.
| Model | GLW01 |
|---|---|
| Cleaning Head | 8 channels and 12 channels |
| Microplate Types | Four kinds, flat bottom, U bottom, V bottom, round bottom |
| Average Residue | <1µL (per hole) |
| Liquid Suction Time | 0.1–999.9 seconds adjustable, with an interval of 0.1 seconds |
| Line Flush Time | 0–240 seconds, adjustable |
| Washing Programs | Up to 200 programs |
| Display | 7-inch touch display |
| Liquid Injection Channels | 3 (2 types of lotion and 1 type of distilled water) |
| Cleaning Needle Position | 6 types (horizontal, left, middle, right, bottom, hole spacing) |
| Consumption | 80W |
| Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz |
| Packing Size (W*D*H) | 690 × 490 × 400 mm |
| Gross Weight | 22 kg |
Digital Microscope for Pathology
Auto-microscope model: Automated digital
microscopy system developed for the
acquisition of high-resolution images in brightfield observation. The
motorized XY sample
stage helps the user to scan a particular sample area automatically and
the autofocusing
system will find the best focused image in each frame before saving it
to the pc for further
analysis.
Transmitted warm white LED illumination along with high quality Plan
achromatic
microscope objective provides uniform illumination of the entire field
of view. The system is
equipped with 5MP USB3.0 CMOS camera for the fast acquisition of the
images and a 60X
Plan objective with 0.85NA for high resolution images. System with user
specified
microscope objective is also available.
A complete user-friendly image acquisition software is provided along
with the system. The
user can easily control the scanning operation and the camera properties
through this
software.
Applications include biological cell imaging, cell counting, malaria
diagnosis, cancel cell imaging
etc.
| Specifications: - | |
|---|---|
| Optical system: Infinity corrected | Camera Details |
| Observation method: Brightfield | Sensor: CMOS, Color, 5Mp |
| Illumination: Transmitted, | Optical format: 1/2.5” |
| Illumination source: High Bright warm White LED, Intensity Adjustable | Active imaging size: 5.70mm x 4.28mm (7.13mm diagonal) |
| Microscope objective: Plan Achromatic 60X, 0.85 NA | Active pixels: 2592 H x 1944 V |
| Focusing: Motorized with Autofocusing | Pixel size: 2.2um x 2.2um |
| Image acquisition: 100 images / 8 Minutes | Frame rate: 14 fps @ full resolution, 45 fps @ 1024x768 |
| Software: AM_V01 | Sensitivity: 1.76V/Lux-sec |
| Exposure time: 109us ~ 3000ms | |
| Spectral range: 380-650nm | |
| XY sample stage - Motorized | SNR: 38.5dB |
| Travel: 18mm x 18mm | Dynamic range: 67.7dB |
| Drive: Stepper Motor | Shutter: Electronic rolling shutter |
| Resolution: 5 microns | Data interface: USB3.0 |
| Accuracy: 5 microns | Software interface: TWAIN\DirectShow |
| Operating mode: Continuous output | |
| Data format: 8 Bit/12 Bit RAW | |
| Picture format: JPEG/BMP/PNG/RAW | |
Brightfield, Phase Contrast, Transmitted Illumination
Inverted microscope suitable for Brightfield and Phase contrast observations. Provisions for mounting different well plates and flasks are provided with the system for imaging living cells or organisms. This model is available in Binocular configuration with a 5MP CMOS camera on the side port. The eyepieces are inclined at 45 degrees and are dioptre adjustable. The smooth-operating, ball bearing mounted, quadruple nosepiece provides effortless objective changes. A mechanical stage with co-axial drops down knob is provided as the sample stage. A tension adjustable coaxial coarse and fine mechanism is used for the sample focusing. Powerful Koehler LED illumination with infinity corrected plan achromatic phase contrast objectives are provided for routine inspection applications. A user-friendly software provides live measurement features, and the measured data can be exported as pdf.
| Model: GLIM01 | |
|---|---|
| Configuration | Inverted |
| Optical system | Infinity corrected |
| Observation method | Brightfield, Phase Contrast |
| Observation Head | Siedentopf Binocular head, 45°, 55–75mm |
| Eyepieces | WF10X, FN20, Dioptric adjustment – both eyepieces |
| Nosepiece | Quadruple revolving, positive precision click stops, Manual. RMS thread |
| Objectives | |
| 1. Plan Achro Phase Contrast 5X/0.10 | WD 1 |
| 2. Plan Achro Phase Contrast 10X/0.25 | WD = 4.3mm, CG=1.2mm |
| 3. Plan Achro Phase Contrast 2X/0.40 | WD = 8mm, CG=1.2mm |
| 4. Plan Achro Phase Contrast 40X/0.60 | WD = 3.5mm, CG=1.2mm |
| Sample stage | Double layer Mechanical stage, Travel = 126mm x 78mm |
| Double layer Mechanical stage | Travel = 126mm × 78mm = T-flask, 96 well plate, 6 well plate, Glass slide, 54mm Petridish |
| Focusing | Coaxial coarse and fine focusing mechanism |
| Condenser | Long working distance, NA = 0.30, WD = 70mm |
| Condenser accessories | Pre-centered Phase slider, Manual |
| Camera Port | Side |
| Transmitted Illumination | 3W white LED, Adjustable intensity |
| Camera | |
| Optical format | 1/2.5” CMOS |
| 1/2.5” CMOS | 5.70mm × 4.28mm |
| Active pixels | 2592 × 1944 (5MP) |
| Pixel size | 2.2 × 2.2 µm |
| Shutter type | Full resolution – 7 fps |
| Frame rate | 380–650nm |
| Spectral response | |
| Exposure time | 0.072ms – 3000ms |
| Image format | RAW, BMP, JPG, PNG |
| Operating temperature | −30 °C to +70 °C |
| Sensitivity | 1.76V/lux-sec (550nm) |
| Interface | USB2.0 |
| USB2.0 | C-mount |
| Software | Micro Analyser (Image grabbing, Live measurements, Reports etc) |
Brightfield, Phase Contrast, Epi-fluorescence
Inverted fluorescence microscope suitable for Brightfield and Phase contrast observations as well. The fluorescence illuminator is equipped with a manually rotatable 4 position fluorescence filter mount and a high bright white LED with adjustable intensity. Fluorescence filter sets are sold separately. Custom LED illumination wavelength can also be provided on special requests. Provisions for mounting different well plates and flasks are provided with the system for observing living cells or organisms. This model is available in Binocular configuration with a 20MP CMOS camera on the side port. The binocular head is inclined at 45 degrees and both the eyepieces are dioptre adjustable. The smooth-operating, ball bearing mounted, quadruple nosepiece provides effortless objective changes. A mechanical stage with co-axial drops down knob is provided as the sample stage. A tension adjustable coaxial coarse and fine mechanism is used for the sample focusing. A Koehler LED transmitted illumination with plan achromatic phase contrast objectives is provided for routine inspection applications. A set of fluorescence objectives are also provided with the system. A user-friendly software provides live measurement features and the measured data can be exported as pdf.
| Model: GLIM02 | |
|---|---|
| Configuration | Inverted |
| Optical system | Infinity corrected |
| Observation method | Brightfield, Phase Contrast, Epifluorescence |
| Observation Head | Siedentopf Binocular head, 45º, 55–75mm IPD |
| Eyepieces | WF10X, FN20, Dioptric adjustment – both eyepieces |
| Nosepiece | Quadruple revolving, positive precision click stops, Manual. RMS thread |
| Objectives | |
| 1. Plan Achro Phase Contrast 5X/0.10 | WD = 9mm, CG=1.2mm |
| 2. Plan Achro Phase Contrast 10X/0.25 | WD = 4.3mm, CG=1.2mm |
| 3. Plan Achro Phase Contrast 20X/0.40 | WD = 8mm, CG=1.2mm |
| 4. Plan Achro Phase Contrast 40X/0.60 | WD = 3.5mm, CG=1.2mm |
| 5. Plan Achromatic 20X/0.40 | WD = 8.8mm |
| 6. Plan Achromatic 40X/0.60 | WD = 3.98mm |
| 7. Plan Achromatic 100X/0.85 dry | WD = 0.40mm |
| Sample stage | |
| Stage type | Double layer Mechanical stage |
| Travel | 126mm × 78mm |
| Sample holders | T-flask, 96 well plate, 6 well plate, Glass slide, 54mm Petri dish |
| Optical & Illumination | |
| Focusing | Coaxial coarse and fine focusing mechanism |
| Condenser | Long working distance, NA = 0.30, WD = 70mm |
| Condenser accessories | Pre-centered Phase slider, Manual |
| Camera Port | Side |
| Transmitted Illumination | 3W white LED, Adjustable intensity |
| Camera | |
| Sensor type | CMOS Color |
| Sensor model | Sony IMX183 |
| Resolution | 5472 × 3648 pixels (20MP) |
| Sensor size | 1” |
| Pixel size | 2.4 µm × 2.4 µm |
| Frame rate | 10 fps @ full resolution |
| Exposure time | 18µs – 15s |
| Data interface | USB 3.0 |
| Shutter | Rolling Shutter |
| Bit depth | 16/8bit |
| Picture format | JPEG/PNG/TIFF |
| Mount | C-mount |
| PC requirements | i5 or above |
| Epi-fluorescence attachment | |
| White LED illumination, intensity adjustable | |
| 4 position fluorescence filter cubes mount | |
| Manually rotatable | |
| (Filter sets are sold separately) | |
| (Custom wavelength LED is available as optional) | |
| Software | Micro Analyser (Image grabbing, Live measurements, Reports etc) |